DGS-3000 Series Layer 2 Managed Gigabit Ethernet Switch CLI Reference Guide
212
d. Sub-option’s length, it should be 4
e. VLAN ID (S-VID)
f.
Module ID, for standalone switch, it is 0; for stacking switch, it is the box ID that
assigned by stacking.
g. Port ID: port number of each box.
vendor1
- If configured to vendor1, the circuit ID uses the following format to communicate with
Alcatel-Lucent’s server:
a.
b.
c.
d.
e.
f.
g.
h.
i.
j.
1
0x10
0
6
VLAN
Slot ID
Port ID 1
6
MAC
1
byte
1
byte
1
byte
1
byte
2
bytes
2
bytes
2
bytes
1
byte
1
byte
6
bytes
a. Sub-option type (1 means circuit ID).
b. Length.
c. Circuit ID’s sub-option’s first tag, it should be 0.
d. First tag’s length, it should be 6.
e. VLAN ID.
f.
Slot ID, for standalone switch, it is 1; for stacking switch, it is the box ID that
assigned by stacking.
g. Port ID: port number of each box.
h. Circuit ID’s sub-option’s second tag, it should be 1.
i.
Second tag’s length, it should be 6.
j.
MAC address: System’s MAC address.
vendor6
- If configured to vendor6, the cicuit ID uses the following:
F01
F02
F03
F04
F05
F06
F07
F08
1
Length
E
(0x45)
t
(0x74)
h
(0x68)
e
(0x65)
r
(0x72)
n
(0x6E)
1 byte
1 byte
1 byte
1 byte
1 byte
1 byte
1 byte
1 byte
F09
F10
F11
F12
F13
F14
F15
F16
e
(0x45)
t
(0x74)
Chassis
ID
/
(0x2F)
0
(0x30)
/
(0x2F)
Port
number
:
(0x3A)
1 byte
1 byte
1-2
bytes
1 byte
1 byte
1 byte
1-2
bytes
1 byte
F17
F18
F19
F20
F21
F22
F23
F24
cvlan
.
(0x2E)
0
(0x30)
Space
(0x20)
System
Name
/
(0x2F)
0
(0x30)
/
(0x2F)
1-4
bytes
1 byte
1 byte
1 byte
1-128
bytes
1 byte
1 byte
1 byte
F25
F26
F27
F28
F29
F30
F31
0
(0x30)
/
(0x2F)
Chassis
ID
/
(0x2F)
0
(0x30)
/
(0x2F)
Port
number
1 byte
1 byte
1-2
bytes
1 byte
1 byte
1 byte
1-2
bytes
F01: Sub-option type (1 means circuit ID).
F02: Length.
F03: Character ‘E’.
F04: Character ‘t’.
F05: Character ‘h’.
F06: Character ‘e’.
F07: Character ‘r’.
F08: Character ‘n’.
F09: Character ‘e’.
F10: Character ‘t’.
F11: Chassis ID. The number of the chassis. For stand-alone devices, the chassis ID
will always be 1. For stacked devices, the chassis ID will be the unit ID.
F12: Slash (/).