358
•
UC-P100-S/UC-P110-S Phones for Skype for Business
Supplemental Guide – DOC. 8412A
Click Stop to stop capturing.
Click Export to open the file download window, and then save the file to the local
system.
Capture the Packets with the Ethernet Software
Data packets can be received from the network hub, or from the phone’s PC port.
To receive data packets from the hub, connect the Internet port of the phone and the PC
to the same hub, and then use packet analyzer software to capture the signal traffic.
To receive data packets from the PC port, connect the Internet port of the phone to the
Internet and the PC port of the phone to a PC. Before capturing the signal traffic, make
sure the data packets can be received from the WAN (Internet) port to the PC (LAN)
port.
The span to PC Port can be configured using the configuration files or locally.
Configuration Methods
Central Provisioning
(Configuration File)
<y0000000000xx>.cfg
Configure the span to PC Port.
Parameter:
static.network.span_to_pc_port
Local
Web User Interface
Configure the span to PC Port.
Navigate to:
http://<phoneIPAddress/servlet?p=networ
k-adv&q=load
Details of the Configuration Parameter
Parameter
Permitted Values
Default
static.network.span_to_pc_port
0 or 1
0
Description:
Enables or disables spanning data packets received from the WAN (Internet) port to the PC
(LAN) port.
0-
Disabled
1-
Enabled, all data packets from WAN (Internet) port can be received by the PC port.
Note: This feature works only if the value of the parameter “static.network.pc_port.enable” is set
to 1 (Auto Negotiate). If the parameter is changed, the phone will reboot to effect the change.
Web User Interface:
Network > Advanced > Span to PC > Span to PC Port
Phone User Interface:
None