Supplemental Guide – DOC. 8412A
UC-P100-S/UC-P110-S Phones for Skype for Business
•
143
Details of the Configuration Parameters
Parameter
Permitted Values
Default
local_time.manual_time_enable
0 or 1
0
Description:
Enables or disables the phone to obtain the time and date from manual settings.
0-
Diabled, obtain the time and date from NTP server
1-
Enabled, obtain the time and date from manual settings
Web User Interface:
Settings > Time & Date > Manual Time
Phone User Interface:
None
local_time.time_format
0 or 1
1
Description:
Configures the time format.
0-
Hour 12, the time will be displayed in 12-hour format with AM or PM specified.
1-
Hour 24, the time will be displayed in 24-hour format (for example, 2:00 PM displays as 14:00).
Web User Interface:
Settings > Time & Date > Time Format
Phone User Interface:
Menu > Setting > Basic > Date & Time > Time & Date Format > Time Format
local_time.date_format
0, 1, 2, 3, 4, 5 or 6
0
Description:
Configures the date format.
Valid values are:
0-
WWW MMM DD
1-
DD-MMM-YY
2-
YYYY-MM-DD
3-
DD/MM/YYYY
4-
MM/DD/YY
5-
DD MMM YYYY
6-
WWW DD MMM
Note: “WWW” represents the abbreviation of the week, “DD” represents a two-digit day, “MMM”
represents the first three letters of the month, “YYYY” represents a four-digit year, and “YY”
represents a two-digit year.
Web User Interface:
Settings > Time & Date > Date Format
Phone User Interface:
Menu > Setting > Basic > Date & Time > Time & Date Format > Date Format