14.16 VFD Display Filter
Flow chart
Image 14-44
Concerned parts
R767246K VFD Display Filter
Necessary tools
None.
How to remove the VFD Display Filter
1.
From the front of the unit push hard on the filter until it detaches from the unit.
Image 14-45
2.
Use alcohol to clean the adhesive residue that held the filter to the metal plate.
How to install the VFD Display Filter
1.
Remove the protective film from the front of the filter and release the liner from the tape.
2.
Press firmly the filter into the metal plate.
14.17 Bottom Panel
Necessary tools
1 x Phillips Screwdriver #2
How to remove the Bottom Panel
1.
Turn the unit over to remove the bottom panel. The bottom panel is composed of two pieces.
2.
Remove the 4 black round-head screws (4-40x1/4) that attach the panels to the side of the unit.
3.
Remove the 6 screws that hold the two sides together.
4.
Remove the rest of the screws from the perimeter of the panel as shown below.
Summary of Contents for Event Master E2 Series
Page 1: ...ENABLING BRIGHT OUTCOMES User s Guide Event Master Devices...
Page 12: ...R5905948 12 Event Master Devices 12...
Page 24: ...R5905948 12 Event Master Devices 24 Safety...
Page 52: ...R5905948 12 Event Master Devices 52 General...
Page 82: ...R5905948 12 Event Master Devices 82 Hardware orientation...
Page 102: ...R5905948 12 Event Master Devices 102 Front Panel Menu orientation...
Page 272: ...R5905948 12 Event Master Devices 272 Image 6 137 EM GUI orientation...
Page 304: ...R5905948 12 Event Master Devices 304 Updating firmware...
Page 326: ...R5905948 12 Event Master Devices 326 Image 9 28 General operation example...
Page 382: ...R5905948 12 Event Master Devices 382 Preventive maintenance actions...
Page 444: ...R5905948 12 Event Master Devices 444 E2 Maintenance...
Page 528: ...R5905948 12 Event Master Devices 528 EC 200 EC 210 Maintenance...
Page 569: ...569 R5905948 12 Event Master Devices Troubleshooting C...
Page 572: ...R5905948 12 Event Master Devices 572 Troubleshooting...