R5905948 /12
Event Master Devices
571
Problem
Possible cause
Remedy
with a VPU card or with the
motherboard. In this case, contact
your Barco customer service
support for further assistance.
The Event Master unit and the PC
running the GUI don
’
t communicate
Cabling/network switch issue
Check all of the Ethernet cables
and verify that they are plugged in.
If you are using a network switch
verify that is on and is operating
properly.
Wrong IP address
IP address is not within your LAN
range.
Conflict between network
addresses: Check if the Event
Master unit network address is not
already in use by another device on
the local network.
DHCP is not enabled.
When the PC running Event Master
Toolset Software is connected
directly with an Event Master unit,
the dynamic configuration (DHCP)
doesn't work.
There is no DHCP server in this
configuration
You need to disable the DHCP
option and enter a static network
address compatible with the PC
running the Event Master control
software (range, Subnet mask,..).
Event Master unit constantly
reboots after a software upgrade
Invalid upgrade (deployment or
defective installation)
Press and hold the
SEL
and
ESC
keys simultaneously until the front
panel shows the choice of
performing a factory reset or
continuing. Performing a factory
reset will allow the Event Master
unit to boot normally. If the problem
persists, contact you local Barco
customer service support for further
assistance.
Can't read or write to or from the
USB drive
Incorrect USB format or bad USB
Ensure that your flash drive is
formatted to use the FAT32 file
system. If you can't access the USB
from a PC, then you have a faulty
USB drive.
The front panel display screen is
too dark
display brightness
Use the
“
VFD brightness
”
sub-
menu in the System menu to adjust
the intensity of the front panel
vacuum fluorescent display (VFD)
screen.
The unit is not responding to any
front panel button presses.
Front panel is locked
To unlock the front panel, press and
hold the
SEL
and
ESC
buttons
simultaneously for 3 seconds.
When the panel is unlocked, the
display screen displays the Status
menu.
After factory reset, the IP address is
lost
Wrong mode of the factory reset
command was used
Use the
“
Factory Reset, Save IP
”
choice in the
“
factory reset
”
sub-
menu when you perform a factory
reset.
Unable to perform web upgrade
Unable to perform web upgrade
Make sure Event Master unit
connection with the LAN is
available.
Make sure there is an internet
access in the LAN
Summary of Contents for Event Master E2 Series
Page 1: ...ENABLING BRIGHT OUTCOMES User s Guide Event Master Devices...
Page 12: ...R5905948 12 Event Master Devices 12...
Page 24: ...R5905948 12 Event Master Devices 24 Safety...
Page 52: ...R5905948 12 Event Master Devices 52 General...
Page 82: ...R5905948 12 Event Master Devices 82 Hardware orientation...
Page 102: ...R5905948 12 Event Master Devices 102 Front Panel Menu orientation...
Page 272: ...R5905948 12 Event Master Devices 272 Image 6 137 EM GUI orientation...
Page 304: ...R5905948 12 Event Master Devices 304 Updating firmware...
Page 326: ...R5905948 12 Event Master Devices 326 Image 9 28 General operation example...
Page 382: ...R5905948 12 Event Master Devices 382 Preventive maintenance actions...
Page 444: ...R5905948 12 Event Master Devices 444 E2 Maintenance...
Page 528: ...R5905948 12 Event Master Devices 528 EC 200 EC 210 Maintenance...
Page 569: ...569 R5905948 12 Event Master Devices Troubleshooting C...
Page 572: ...R5905948 12 Event Master Devices 572 Troubleshooting...