background image

Istruzioni assemblaggio – Assembly instructions 

Serie DT – MR – MW – MC – MS – FP  

 

           MK – VT – P1509 – P1507 – TP – TPS – TPM

 

  

DOC00032.doc Rev. D 

1/8

 

Proprietà dell’azienda Dana Incorporated vietata qualsiasi riproduzione anche parziale senza l’autorizzazione della stessa.        ISTRUZIONI ORIGINALI 
Property of Dana Incorporated. Reproduction in whole or in part without express written consent is prohibited.                      ORIGINAL INSTRUCTIONS 

 

 

      

 

Dana Incorporated 
Dana Brevini Fluid Power S.p.A.

 

Via Moscova, 6 – 42124 Reggio Emilia (RE) – Italy 
Tel. +39 0522 270711 
www.dana.com/brevini 
[email protected]                    

 
 

INDICE 

LEGENDA ACRONIMI E SIMBOLI .................................................. 1

 

CARATTERISTICHE GENERALI DEL MANUALE .......................... 1

 

USO PREVISTO DELLA UNITÀ DI POTENZA ................................ 2

 

LIMITI DI IMPIEGO ......................................................................... 2

 

SPECIFICHE DI SICUREZZA ......................................................... 3

 

IDENTIFICAZIONE DEL PRODOTTO ............................................. 3

 

CONFORMITÀ ALLE DIRETTIVE ................................................... 3

 

LIMITI DI FUNZIONAMENTO .......................................................... 4

 

STOCCAGGIO ................................................................................ 4

 

SCELTA DEL FLUIDO IDRAULICO ................................................ 4

 

INSTALLAZIONE ............................................................................ 5

 

Norme generali per una corretta installazione ............................................................... 5

 

Collegamento elettrico per motore DC .......................................................................... 5

 

Collegamento motore AC .............................................................................................. 6

 

Collegamento valvola ad intervento elettrico ................................................................. 6

 

Collegamento idraulico .................................................................................................. 6

 

Montaggio leva comando manuale ................................................................................ 6

 

AVVIAMENTO ................................................................................. 7

 

RACCOMANDAZIONI ..................................................................... 7

 

MANUTENZIONE ............................................................................ 7

 

Sostituzione del filtro ..................................................................................................... 8

 

Smontaggio e rimontaggio dei serbatoi ......................................................................... 8

 

Serraggi consigliati ........................................................................................................ 8

 

DEMOLIZIONE E SMALTIMENTO .................................................. 8

 

  

LEGENDA ACRONIMI E SIMBOLI 

UP 

Unità di potenza, centralina idraulica 

AC 

Corrente alternata 

DC 

Corrente continua 

VM 

Valvola di massima 

CW 

Orario 

 

Le  operazioni  che  rappresentano  una  situazione  di 
potenziale  pericolo  per  persone,  animali  o  cose  sono 
evidenziate tramite il simbolo riportato a fianco. 

 

Le operazioni che necessitano di particolare attenzione per 
il  buon  funzionamento  dell’  impianto  sono  evidenziate 
tramite il simbolo riportato a fianco. 

 

Coppia di serraggio da applicare, espressa in Nm 

 

CARATTERISTICHE GENERALI DEL MANUALE 
Il  presente  manuale  fa  riferimento  alle  unità  di  potenza  (di  seguito  UP)  
serie DT, MR, MW, MC, MS, FP, MK, VT, P1509, P1507, TP, TPS, TPM. 
L’ Utilizzatore è il solo responsabile dell’ uso di questo manuale. Il rischio 
relativo  è  assunto  completamente  dall’  Utilizzatore.  In  nessun  caso  la 
Dana  Brevini  Fluid  Power  S.p.A.  sarà  responsabile  per  danni  speciali, 
indiretti,  accidentali  o  consequenziali  dipendenti  dall’  uso  o  dall’ 
inesperienza  nell’  utilizzo  del  manuale  o  del  prodotto.  DANA  non  sarà 
responsabile  per  una  cattiva  od  impropria  installazione,  manutenzione, 
riparazione del prodotto, anche nei confronti di terzi, nonché per l’ utilizzo 
di  ricambi  non  originali.  Nessuna  parte  di  questo  manuale  può  essere 
riprodotta in qualsiasi forma o mezzo, per qualsiasi uso, che non sia quello 

TABLE OF CONTENTS 

LEGEND OF ABBREVIATIONS AND SYMBOLS ............................ 1

 

GENERAL INSTRUCTIONS FOR THE USE OF THIS MANUAL ..... 1

 

PRESCRIBED USE OF THIS POWER UNIT ................................... 2

 

LIMITS OF USE............................................................................... 2

 

SAFETY SPECIFICATIONS ............................................................ 3

 

IDENTIFYING THE UNIT................................................................. 3

 

COMPLIANCE WITH DIRECTIVES ................................................. 3

 

OPERATIONAL LIMITS ................................................................... 4

 

STORAGE ....................................................................................... 4

 

CHOOSING THE HYDRAULIC FLUID ............................................ 4

 

INSTALLATION ............................................................................... 5

 

General rules for correct installation .............................................................................. 5

 

Connecting a DC motor ................................................................................................. 5

 

Connecting an AC motor ............................................................................................... 6

 

Connecting electrically actuated valves ......................................................................... 6

 

Hydraulic connection ..................................................................................................... 6

 

Installation of manual pressure control group ................................................................ 6

 

START UP....................................................................................... 7

 

TIPS ................................................................................................ 7

 

MAINTENANCE .............................................................................. 7

 

Replacing the filter ......................................................................................................... 8

 

Removing and reinstalling the tanks .............................................................................. 8

 

Recommended tightening torque values ....................................................................... 8

 

DISMANTLING AND DISPOSAL ..................................................... 8

 

  

LEGEND OF ABBREVIATIONS AND SYMBOLS 

HPU 

Hydraulic power unit 

AC 

Alternating current 

DC 

Direct current 

RV 

Relief valve 

CW 

Clockwise 

 

Operations  that  may  create  a  dangerous  situation  to 
persons, animals or property are indicated by the symbol on 
the left. 

 

Procedures  that  require  special  attention  to  obtain  proper 
system operation are indicated by the symbol on the left. 
 

 

Tightening torque to be applied, in Nm 

 

GENERAL INSTRUCTIONS FOR THE USE OF THIS MANUAL 
This manual applies to hydraulic power units (hereafter called HPU) of the 
following series: DT, MR, MW, MC, MS, FP, MK, VT, P1509, P1507, TP, 
TPS, TPM. The User is solely responsible for the use of this manual and 
completely assumes the relative risk. Dana Brevini Fluid Power S.p.A. will 
not  be  responsible  for  special,  indirect,  accidental  or  consequential 
damage  deriving  from  the  use  of  this  manual  or  the  product,  or  from 
inexperience with the use of this manual or of the product. DANA will not 
be  responsible  -  even  to  third  parties  -    for  poor  or  improper  installation, 
maintenance,  or  repair  of  the  product,  or  for  the  use  of  non-original 
replacement  parts.  This  manual  may  not  be  reproduced,  in  whole  or  in 
part,  in  any  form  or  by  any  means,  for  any  use  which  is  not  the  User’s 

 

Apply label 

Summary of Contents for DT Series

Page 1: ...ti accidentali o consequenziali dipendenti dall uso o dall inesperienza nell utilizzo del manuale o del prodotto DANA non sar responsabile per una cattiva od impropria installazione manutenzione ripar...

Page 2: ...a tenuta perfetta pertanto tale caratteristica deve essere considerata dall Utilizzatore in sede di progettazione della propria macchina o attrezzatura Le UP subiscono un collaudo funzionale e di veri...

Page 3: ...CE Motore AC Trifase e Monofase non applicabile Motore DC Campi avvolti conforme Motore DC Magneti permanenti non conforme compito dell Utilizzatore predisporre un filtro antidisturbo sulla linea di...

Page 4: ...le loro inferiori prestazioni nei confronti della temperatura Temperature ottimale di utilizzo dei serbatoi in lamiera e polietilene PE 10 C ambientale 70 C di esercizio Temperature limite di utilizzo...

Page 5: ...are la sezione e la lunghezza dei cavi di alimentazione sezioni troppo piccole e lunghezze troppo elevate possono causare cadute di tensione tali da compromettere il buon funzionamento della UP Prima...

Page 6: ...montato ingrassare le parti interne del gruppo leva e della valvola sulla quale il gruppo leva deve essere montato grasso per guarnizioni introdurre il gruppo leva fino al contatto fra camma e perno...

Page 7: ...rettamente il serbatoio vedere capitoli Smontaggio dei serbatoi e Sostituzione del filtro Prima di effettuare il cambio del fluido idraulico svuotare completamente tutto l impianto La frequenza del ca...

Page 8: ...la suddivisione tra le parti in acciaio e quelle in altri metalli o leghe per un corretto invio al riciclaggio per fusione L operazione di demolizione non presenta rischi particolari a condizione che...