R5905948 /12
Event Master Devices
554
B.1 Event Master series processor ASCII remote
control
General
The user can remotely control the Event Master series processor via a telnet connection to the unit
’
s IP
address.
How to access the Event Master series processor remotely
To access the Event Master series processor remote commands, use the following procedure:
1.
In a command prompt window, type a telnet command in the following format:
> telnet nnn.nnn.nnn.nnn 9878
where the n
’
s represent the unit IP address and 9878 is the port.
2.
Press
Enter
The command prompt appears.
3.
At the command prompt, type a specific Event Master series processor remote control command and press
Enter.
ASCII remote commands
This section lists the Event Master series processor remote commands, sorted by name.
ATRN
•
Description: Performs an Auto Transition on the currently active destinations. The currently selected Effect
type, rate and edge width will be used to transition preview to program.
•
Command Format: ATRN <transTime>
•
Parameters:
<transTime> (optional)
Used to specify a transition time (duration of the transition) in frames. Value ranges from 0 to 1999. A 0
specify a cut transition. Any non-zero value (within range) will override the transition time in the controller. If
this argument is not specified, the current transition time known by the controller will be used.
•
Examples:
> ATRN 200
(Transition Preview to Program on currently active destinations in 200 frames)
> ATRN 0
(Transition Preview to Program immediately. This is a CUT.)
> ATRN
(Transition Preview to Program using the transition time set in the controller)
•
Query Format: N/A
•
Query Response: N/A
PRESET
•
Description: Preset Settings. For parameter details, see below.
•
Command Format: PRESET
•
Parameters:
-s (save preset, 1-1000)
-r (recall preset, 1-1000)
-a (recall preset and auto transition, 1-1000)
•
Examples:
> PRESET -s 1
(Save currently selected destinations to preset 1)
> PRESET -r 10
(Recall preset 10)
Summary of Contents for Event Master E2 Series
Page 1: ...ENABLING BRIGHT OUTCOMES User s Guide Event Master Devices...
Page 12: ...R5905948 12 Event Master Devices 12...
Page 24: ...R5905948 12 Event Master Devices 24 Safety...
Page 52: ...R5905948 12 Event Master Devices 52 General...
Page 82: ...R5905948 12 Event Master Devices 82 Hardware orientation...
Page 102: ...R5905948 12 Event Master Devices 102 Front Panel Menu orientation...
Page 272: ...R5905948 12 Event Master Devices 272 Image 6 137 EM GUI orientation...
Page 304: ...R5905948 12 Event Master Devices 304 Updating firmware...
Page 326: ...R5905948 12 Event Master Devices 326 Image 9 28 General operation example...
Page 382: ...R5905948 12 Event Master Devices 382 Preventive maintenance actions...
Page 444: ...R5905948 12 Event Master Devices 444 E2 Maintenance...
Page 528: ...R5905948 12 Event Master Devices 528 EC 200 EC 210 Maintenance...
Page 569: ...569 R5905948 12 Event Master Devices Troubleshooting C...
Page 572: ...R5905948 12 Event Master Devices 572 Troubleshooting...