0906004 (0,4L)
0902010 (1L)
0,4L or 1L
ABX Diagnostics
BP 7290 - 34184 Montpellier
cedex 4 - France
S.A. au capital de 44.000.000Euros
- RCS Montpellier 328 031 042 - SIRET 328 031 042 000 42 - APE 332 B
12/05/03
A95A00009-A
Hematology ABX Devices
(for in vitro diagnostic use)
ABX
ALphalyse
Exclusive use:
Hematology ABX device
Exclusive
Micros CRP
ü
Pentra 60
ü
Pentra 60 C+
ü
Pentra 80
ü
Pentra XL 80
ü
Pentra 120
ü
Pentra 120 Retic
ü
Pentra DX 120
ü
Slide Preparation System
ABX Alphalyse
1. Functions
Lysing agent for white blood cell counting, and hemoglobin
determination on ABX blood cell counters.
Measurement procedure to be followed in using the device
:
Principle of the method, specific analytical performance
characteristics, analytical sensitivity, diagnostic sensitivity, analytical
specificity, diagnostic specificity, accuracy, repeatability,
reproducibility, limits of detection, limitations of the method and
information about the use of available reference measurement
procedures and materials by the user: see «Section: Specifications» in
the instrument User Manual.
2. Conservation & expiration
Storage conditions
: stored at 18°C (65°F) to 25°C (77°F) away from
light. Product will degrade if exposed to air, keep cap / probe assembly
securely tightened.
Expiration date
: refer to «expiration date» reagent packaging label.
3. Measurements, principles & results
Directions for use
: see «Section: Maintenance & Troubleshooting /
Reagent Location and connection» in the instrument User Manual.
This reagent is for professional
in-vitro
diagnostic use only.
Measuring Principles
: see «Section: Description & technology» in the
instrument User Manual.
Results
: see «Section: Workflow» in the instrument User Manual
Performance data
: see «Section: Specifications» in the instrument
User Manual.
Note: if performance changes, call your ABX Diagnostics
representative.
4. Composition & handling precautions
Composition
:
Potassium Cyanide.................0,03 %
Quaternary Amonium Salt.......< 3 %
Description
: aqueous solution, limpid.
Handling Precautions
: Avoid contact with eyes, skin and clothing.
Wear laboratory gloves when handling the product. The product may
be harmful if ingested. The product can be absorbed through an open
wound, or inhalation. Please refer to the MSDS associated with the
reagent.
Special precautions
: Avoid contact with acid and aqueous acid
environment: extremely toxic cyanide acid vapour can be formed.
Please refer to the MSDS associated with the reagent.
Specimen Collection and Mixing
: see «Section: Workflow» in the
instrument User Manual
Limitations
: see «Section: Specifications» in the instrument User
Manual
Safe Waste Disposal
: see «Section: Specifications» in the instrument
User Manual. Please refer to the MSDS associated with the reagent.
pH
:
10 +/- 0,5
(
T=20°C)
Resistivity
:
213 +/- 10
W (
T=20°C)
Summary of Contents for Pentra 80 RAB108EA
Page 1: ...User Manual P n RAB108EA ABX Diagnostics B P 7290 34184 MONTPELLIER Cedex 4 FRANCE...
Page 12: ...10 Section9 Glossary 1 Glossary 9 2 2 Index 9 4 3 9 11...
Page 87: ...Quality Assurance Calibration Pentra 80 User Manual RAB108EA 3 31 Fig 3 29 Delete options...
Page 162: ...Pentra 80 5 10 Pentra 80 User Manual RAB108EA Fig 5 6 Units tab...
Page 194: ...Pentra 80 5 42 Pentra 80 User Manual RAB108EA...
Page 214: ...Pentra 80 6 20 Pentra 80 User Manual RAB108EA...