Note
Action
Tweezers
Disconnect the connectors from the drive board.
•
D6.X1
•
D6.DC+
•
D6.DC-
•
D6.X4
•
D6.X2
•
D6.X5
CAUTION
Use tweezers to unlock connectors and pull them
off.
4
xx2000002164
Removing the axis-6 joint unit
Note
Action
Lifting aid: 3HAC077789-001
Fit the lifting aid to the joint unit, on the torque
sensor side.
CAUTION
The connectors and the joint unit cables are
sensitive to mechanical damage. Handle the as-
sembly with care.
1
Screws: M3x12 (4 pcs)
xx2000002168
Position shown in the figure shows
axis 5 jogged to +20°, which is a
more convenient position when re-
placing only the axis-6 joint unit.
xx2000002170
Remove two attachment screws.
Dispose the screws.
New screws are included in the spare part delivery
of the joint unit.
2
Position shown in the figure shows
axis 5 jogged to +20°, which is a
more convenient position when re-
placing only the axis-6 joint unit.
Continues on next page
992
Product manual - CRB 15000
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.6.7 Replacing the axis-5 joint unit and the axis-5 to axis-6 transition cabling
Continued
Summary of Contents for CRB 15000
Page 1: ...ROBOTICS Product manual CRB 15000 ...
Page 8: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 38: ...This page is intentionally left blank ...
Page 54: ...This page is intentionally left blank ...
Page 182: ...This page is intentionally left blank ...
Page 200: ...This page is intentionally left blank ...
Page 1058: ...This page is intentionally left blank ...
Page 1076: ...This page is intentionally left blank ...
Page 1095: ......