
Note
Action
xx2100000301
Remove the protection plate.
10
Connecting the axis-1 joint unit cabling
Note
Action
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling
the unit read the safety information in section
The unit is sensitive to ESD on page 53
.
1
xx2000002009
Reconnect the connectors to the drive board.
•
D1.X1 to X1
•
D1.DC+ to DC+
•
D1.DC- to Ground
•
D1.X4 to X4
•
D1.X2 to X2
•
D1.X5 to X5
•
DR.X8 to X8
2
Continues on next page
Product manual - CRB 15000
257
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.3.2 Replacing the axis-1 cabling
Continued
Summary of Contents for CRB 15000
Page 1: ...ROBOTICS Product manual CRB 15000 ...
Page 8: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 38: ...This page is intentionally left blank ...
Page 54: ...This page is intentionally left blank ...
Page 182: ...This page is intentionally left blank ...
Page 200: ...This page is intentionally left blank ...
Page 1058: ...This page is intentionally left blank ...
Page 1076: ...This page is intentionally left blank ...
Page 1095: ......