Refitting the lower and upper arm assembled (-5/0.95)
Note
Action
Guide pin, M4x120: 3HAC077786-
001
Fit two guide pins to the axis-2 joint unit.
1
xx2000001949
Cleaning agent: Isopropanol
Remove any old residuals of flange sealant from
the lower arm mounting surface and clean with
isopropanol.
2
Flange sealant: Loctite 574
xx2000001963
Apply new flange sealant to the corner of the
lower arm mounting surface, as pointed out in the
figure.
CAUTION
The weight of the complete upper and lower arm
together is 18 kg
3
xx2000001941
Lift the upper and lower arm assembly to mount-
ing position and slide it onto the guide pins.
4
Continues on next page
324
Product manual - CRB 15000
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.3.3 Replacing the axis-2 cabling
Continued