Note
Action
xx2000002051
Orient the cable plate according to the figure.
The circle on the cable plate should point towards
the guide pin on the torque sensor.
3
Hex socket head cap screw:
M2.5x6 12.9 Lafre 2C2B/FC6.9 (4
pcs)
Secure the cable plate to the joint unit with the
attachment screws.
4
Tightening torque: 0.45 Nm.
xx2000002049
xx2000002053
Connect the two connectors to the torque sensor
board.
•
TQ.A to CH1/A
•
TQ.B to CH2/B
5
Continues on next page
Product manual - CRB 15000
329
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.3.3 Replacing the axis-2 cabling
Continued