Refitting the axis-1 joint unit (-10/1.52 and -12/1.27)
Note
Action
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
unit is sensitive to ESD on page 53
1
O-ring: 3HAC061327-044
Check the o-rings.
2
xx2300000823
Replace if damaged.
Guide pin, M5x150: 3HAC087786-
001
Fit two guide pins to the base.
3
Always use guide pins in pairs.
For joint units on axes 1 and 2 of
CRB 15000-10/1.52 and CRB
15000-12/1.27.
xx2300000775
Continues on next page
700
Product manual - CRB 15000
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.5.1 Replacing the base
Continued