3.4.2 Customer connections on the manipulator
Introduction
The customer cables are routed internally with the manipulator cable harness.
Customer cabling
Note
Rating in each
wire
i
Article number
Cable specifica-
tion
Customer con-
nection
Routed internally
with the manipu-
lator cable har-
ness.
24V
ii
1.5A
See
Product
manual, spare
parts - CRB
15000
Raw cable is
twisted pair
1x2xAWG24
Customer power
(CP)
Routed internally
with the manipu-
lator cable har-
ness.
24V
iii
500mA
See
Product
manual, spare
parts - CRB
15000
2x2xAWG26 in
4x2XAWG26
cable
Customer signal
(CS)
i
Stresses above the limitation may cause permanent damage to the manipulator.
ii
Rated 24V, max 30V
iii
Rated 24V, max 30V
Continues on next page
Product manual - CRB 15000
101
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
3 Installation and commissioning
3.4.2 Customer connections on the manipulator