Removing the joint cabling (-5/0.95)
Use these procedures to remove the joint-1 cabling.
Preparations before removing the cabling
Note
Action
xx2100000044
Jog the robot to the specified position: xxx
•
Axis 1: 0°
•
Axis 2: 0°
•
Axis 3: +60°
•
Axis 4: 0°
•
Axis 5: -90°
•
Axis 6: No significance.
1
CAUTION
Turn off all supplies for electrical power to the
robot, before starting the repair work.
2
Removing the lower arm covers (-5/0.95)
Note
Action
CAUTION
Make sure that all supplies for electrical power
are turned off.
1
Continues on next page
224
Product manual - CRB 15000
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.3.2 Replacing the axis-1 cabling
Continued
Summary of Contents for CRB 15000
Page 1: ...ROBOTICS Product manual CRB 15000 ...
Page 8: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 38: ...This page is intentionally left blank ...
Page 54: ...This page is intentionally left blank ...
Page 182: ...This page is intentionally left blank ...
Page 200: ...This page is intentionally left blank ...
Page 1058: ...This page is intentionally left blank ...
Page 1076: ...This page is intentionally left blank ...
Page 1095: ......