Setting the configuration to locked
When the responsible safety user has approved the validation of the configuration,
the status of the configuration should be changed to
Locked
on the FlexPendant.
Running the robot in auto mode with the configuration unlocked will result in a
warning message.
1 Log in as a user with the grant
Lock Safety Controller Configuration
.
2 In the
Settings
app, select the
Safety Controller
, and then
Configuration
.
3 Select the check box
Locked
.
Concluding steps
After the validation is concluded, turn on the the
SafeMove Assistant
functionality,
with the system parameter
Disable SafeMove Assistant
.
Product manual - CRB 15000
131
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.