Connecting the axis-3 joint unit cabling
Note
Action
xx2000002068
Reconnect the connectors to the drive board.
•
D3.X1 to X1
•
D3/4.DC+ to DC+
•
D3/4.DC- to Ground
•
D3.X4 to X4
•
D3/4.X2 to X2
•
D3.X5 to X5
1
xx2000002067
Connect the connectors to each other and snap
them to the cable holders.
•
J4.DC+ to J4/5.DC+
•
J4.DC- to J4/5.DC-
•
J4.CS to J4/5.CS
•
J4.CP to J4/5.CP
2
Hex socket head cap screw: M3x6 (1
pcs).
Secure the cables for functional earth and
protective earth with a screw.
3
Tightening torque: 0.8 Nm.
xx2000001945
Continues on next page
Product manual - CRB 15000
551
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.4.2 Replacing the housing