7 In the
Visual SafeMove
browser, right-click
Tool Speed Supervisions
and
choose
Create Global Tool Speed Supervision
.
Value
Parameter
ISH_Supervise_TSP
Activation
ISH_TSP_Active
Function active status
Category1Stop
Stop category
Violation action
ISH_TSP_Viol
Signal
250.000
Max speed (mm/s)
Settings
Leave blank
Min speed (mm/s)
8 In the
Visual SafeMove
browser, right-click
Stand Still Supervisions
and
choose
Create Global Stand Still Supervision
.
Value
Parameter
ISH_Supervise_SST
Activation
ISH_SST_Active
Function active status
Category0Stop
Stop category
Violation action
ISH_SST_Viol
Signal
Enabled for all joints and remain
default tolerance values.
Tolerances
Uploading the settings to the controller
1 In the
Visual SafeMove
ribbon tab, click
Controller
in the
Configuration
group.
2 Click
Write to controller
.
The configurations are uploaded to the controller after the controller restarts.
140
Product manual - CRB 15000
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
3 Installation and commissioning
3.6.5 Configuration of SafeMove using Visual SafeMove in RobotStudio
Continued
Summary of Contents for CRB 15000
Page 1: ...ROBOTICS Product manual CRB 15000 ...
Page 8: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 38: ...This page is intentionally left blank ...
Page 54: ...This page is intentionally left blank ...
Page 182: ...This page is intentionally left blank ...
Page 200: ...This page is intentionally left blank ...
Page 1058: ...This page is intentionally left blank ...
Page 1076: ...This page is intentionally left blank ...
Page 1095: ......