![background image](http://html1.mh-extra.com/html/abb/acs880-x04/acs880-x04_firmware-manual_3389539224.webp)
224 Parameters
Selects the source for enabling/disabling speed reference
ramp balancing.
This function is used to generate a smooth transfer from a
torque- or tension-controlled motor back to being speed-
controlled. The balancing output would be tracking the
present “line” speed of the application and when transfer is
required, the speed reference can then be quickly “seeded” to
the correct line speed. Balancing is also possible in the speed
controller, see parameter
.
0 = Disabled
1 = Enabled
Not selected
0.
0
Selected
1.
1
DI1
Digital input DI1 (
, bit 0).
2
DI2
Digital input DI2 (
, bit 1).
3
DI3
Digital input DI3 (
, bit 2).
4
DI4
Digital input DI4 (
, bit 3).
5
DI5
Digital input DI5 (
, bit 4).
6
DI6
Digital input DI6 (
, bit 5).
7
DIO1
Digital input/output DIO1 (
, bit 0).
10
DIO2
Digital input/output DIO2 (
, bit 1).
11
). -
Defines the reference for speed ramp balancing. The output of
the ramp generator is forced to this value when balancing is
enabled by parameter
.
0.00 rpm
-30000.00 …
30000.00 rpm
Speed ramp balancing reference.
See par.
No.
Name/Value
Description
Def
/
FbEq16
Summary of Contents for ACS880-x04
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 primary control program Firmware manual ...
Page 4: ......
Page 18: ...18 Using the control panel ...
Page 24: ...24 Control locations and operating modes ...
Page 112: ...112 Application macros ...
Page 496: ...496 Additional parameter data ...
Page 544: ...544 Fault tracing ...
Page 602: ...602 Control chain diagrams ...