26 Program features
Drive configuration and programming
The drive control program is divided into two parts:
• firmware program
• application program.
The firmware program performs the main control functions, including speed and
torque control, drive logic (start/stop), I/O, feedback, communication and protection
functions. Firmware functions are configured and programmed with parameters, and
can be extended by application programming.
Programming via parameters
Parameters configure all of the standard drive operations and can be set via
• the control panel, as described in chapter
• the Drive composer PC tool, as described in
Drive composer user’s manual
(3AUA0000094606 [English]), or
• the fieldbus interface, as described in chapters
embedded fieldbus interface (EFB)
and
Fieldbus control through a fieldbus
.
All parameter settings are stored automatically to the permanent memory of the drive.
However, if an ex24 V DC power supply is used for the drive control unit, it is
highly recommended to force a save by using parameter
before powering down the control unit after any parameter changes have
been made.
If necessary, the default parameter values can be restored by parameter
Application program
Firmware
Speed control
Torque control
Frequency control
Drive logic
I/O interface
Fieldbus interface
Protections
Feedback
Standard
block library
Function block
program
Drive control program
Parameter
interface
M
Summary of Contents for ACS880-x04
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 primary control program Firmware manual ...
Page 4: ......
Page 18: ...18 Using the control panel ...
Page 24: ...24 Control locations and operating modes ...
Page 112: ...112 Application macros ...
Page 496: ...496 Additional parameter data ...
Page 544: ...544 Fault tracing ...
Page 602: ...602 Control chain diagrams ...