330 Parameters
Defines the brake open delay, ie. the delay between the
internal open brake command and the release of motor speed
control. The delay timer starts when the drive has magnetized
the motor and increased the motor torque to the level required
for brake release (parameter
). Simultaneously with the timer start, the brake
control logic energizes the brake control output and the brake
starts to open.
Set this parameter to the value of mechanical opening delay
specified by the brake manufacturer.
0.00 s
0.00 … 5.00 s
Brake open delay.
100 = 1 s
Defines a source that is used as a brake opening torque
reference if
• its absolute value is greater than the setting of parameter
, and
• its sign is the same as the setting of
.
See parameter
Zero
Zero.
0
AI1 scaled
(see page
).
1
AI2 scaled
(see page
).
2
FBA ref1
(see page
3
FBA ref2
(see page
4
Brake torque
memory
7
Brake open torque
Parameter
.
8
). -
Defines the sign (ie. direction of rotation) and minimum
absolute value of the brake open torque (motor torque
requested at brake release in percent of motor nominal
torque).
The value of the source selected by parameter
is used as the brake open torque only if it
has the same sign as this parameter and has a greater
absolute value.
Note:
This parameter is not effective in scalar motor control
mode.
0.0%
-1600.0 … 1600.0% Minimum torque at brake release.
See par.
Selects a source that prevents the brake from opening.
0 = Normal brake operation
1 = Keep brake closed
Note:
This parameter cannot be changed while the drive is
running.
Not selected
0.
0
Selected
1.
1
DI1
Digital input DI1 (
, bit 0).
2
DI2
Digital input DI2 (
, bit 1).
3
DI3
Digital input DI3 (
, bit 2).
4
DI4
Digital input DI4 (
, bit 3).
5
No.
Name/Value
Description
Def
/
FbEq16
Summary of Contents for ACS880-x04
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 primary control program Firmware manual ...
Page 4: ......
Page 18: ...18 Using the control panel ...
Page 24: ...24 Control locations and operating modes ...
Page 112: ...112 Application macros ...
Page 496: ...496 Additional parameter data ...
Page 544: ...544 Fault tracing ...
Page 602: ...602 Control chain diagrams ...