Parameters 409
(Visible when an absolute encoder is selected)
See parameter
(Visible when an absolute encoder is selected)
See parameter
(Visible when an absolute encoder is selected)
See parameter
(Visible when an absolute encoder is selected)
See parameter
.
64
94
Control of the supply unit of the drive, such as DC voltage and
reactive power reference.
Note that the references defined here must also be selected
as the reference source in the supply control program to be
effective.
This group is only visible when supply unit control has been
activated by parameter
See also section
Control of a supply unit (LSU)
).
Enables/disables the internal INU-LSU state machine.
When the state machine is enabled, the inverter unit (INU)
controls the supply unit (LSU) and prevents the inverter unit
from starting until the supply unit is ready.
When the state machine is disabled, the status of the supply
unit (LSU) is ignored by the inverter unit.
Off
INU-LSU state machine disabled.
0
On
INU-LSU state machine enabled.
1
Enables/disables control panel and PC tool access to the
supply unit (line-side converter) via the inverter unit (motor-
side converter).
Note:
This feature is only supported by the following drives:
• ACS880-11
• ACS880-31
• ACS880-17 based on an integrated drive module
• ACS880-37 based on an integrated drive module.
Disable
Control panel and PC tool access to supply unit via inverter
unit disabled.
0
Enable
Control panel and PC tool access to supply unit via inverter
unit enabled.
1
(Only visible with certain drive types.)
Selects the functionality of bit 1 of
.
ABB single drives
standard SW
The drive sets bit 1 of
after the DC link
is charged.
0
Backwards
compatible SW
The drive sets bit 1 of
after the main
contactor is closed and the supply unit (line-side converter) is
running.
This setting can be used eg. when installing the drive into an
existing set-up with other ACS880 as well as ACS800 drives.
1
Defines the maximum time the supply unit (LSU) is allowed for
charging before a fault (
) is generated.
15 s
0…65535 s
Maximum charging time.
1 = 1 s
No.
Name/Value
Description
Def
/
FbEq16
Summary of Contents for ACS880-x04
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 primary control program Firmware manual ...
Page 4: ......
Page 18: ...18 Using the control panel ...
Page 24: ...24 Control locations and operating modes ...
Page 112: ...112 Application macros ...
Page 496: ...496 Additional parameter data ...
Page 544: ...544 Fault tracing ...
Page 602: ...602 Control chain diagrams ...