Parameters 125
ACS800-compatible fault word 2.
The bit assignments of this word correspond to FAULT WORD
2 in the ACS800. Parameter
determines whether the bit assignments are
according to the ACS800 Standard or ACS800 System control
program.
Each bit can indicate several ACS880 events as listed below.
This parameter is read-only.
-
0000h…FFFFh
ACS800-compatible fault word 2.
1 = 1
(Only visible with a BCU control unit)
Indicates which parallel-connected modules have faulted.
The bits of this word are cleared when all faults have been
reset.
This parameter is read-only.
-
0000h…FFFFh
Faulted modules indication.
1 = 1
No.
Name/Value
Description
Def
/
FbEq16
Bit
ACS800 fault name
ACS880 events indicated by this bit
(see
, page
)
(
=
)
0
SUPPLY PHASE
SUPPLY PHASE
1
NO MOT DATA
NO MOTOR DATA -
2
DC UNDERVOLT
DC UNDERVOLT
3
Reserved
CABLE TEMP
4
RUN ENABLE
RUN DISABLE
5
ENCODER ERR
ENCODER ERR
6
I/O COMM
IO COMM ERR
7
CTRL B TEMP
CTRL B TEMP
-
8
EXTERNAL FLT
SELECTABLE
9
OVER SWFREQ
OVER SWFREQ
-
10
AI < MIN FUNC
AI<MIN FUNC
11
PPCC LINK
PPCC LINK
,
12
COMM MODULE
COMM MODULE
13
PANEL LOSS
PANEL LOSS
14
MOTOR STALL
MOTOR STALL
15
MOTOR PHASE
MOTOR PHASE
Bit
Name
Description
0
Module 1
1 = Module 1 faulted
1
Module 2
1 = Module 2 faulted
…
…
…
11
Module 12
1 = Module 12 faulted
12…15 Reserved
Summary of Contents for ACS880-x04
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 primary control program Firmware manual ...
Page 4: ......
Page 18: ...18 Using the control panel ...
Page 24: ...24 Control locations and operating modes ...
Page 112: ...112 Application macros ...
Page 496: ...496 Additional parameter data ...
Page 544: ...544 Fault tracing ...
Page 602: ...602 Control chain diagrams ...