Program features 91
Miscellaneous
User parameter sets
The drive supports four user parameter sets that can be saved to the permanent
memory and recalled using drive parameters. It is also possible to use digital inputs to
switch between user parameter sets.
A user parameter set contains all editable values in parameter groups 10…99 except
• forced I/O values such as parameters
• I/O extension module settings (groups 14…16)
• fieldbus communication enable parameters (
• other fieldbus communication settings (groups 51…56 and 58)
• encoder configuration settings (groups 92…93),
• some hardware settings in parameter group
, and
• user set selection parameters
As the motor settings are included in the user parameter sets, make sure the settings
correspond to the motor used in the application before recalling a user set. In an
application where different motors are used with the drive, the motor ID run needs to
be performed with each motor and the results saved to different user sets. The
appropriate set can then be recalled when the motor is switched.
If no parameter sets have been saved, attempting to load a set will create all sets
from the currently active parameter settings.
Switching between user parameter sets is only possible with the drive stopped.
Settings
Parameters
(page
).
Parameter checksum calculation
A parameter checksum can be calculated from a user-definable set of parameters to
monitor changes in the drive configuration. The calculated checksum is compared to
1…4 reference checksums; in case of a mismatch, an event (a pure event, warning or
fault) is generated.
Summary of Contents for ACS880-x04
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 primary control program Firmware manual ...
Page 4: ......
Page 18: ...18 Using the control panel ...
Page 24: ...24 Control locations and operating modes ...
Page 112: ...112 Application macros ...
Page 496: ...496 Additional parameter data ...
Page 544: ...544 Fault tracing ...
Page 602: ...602 Control chain diagrams ...