3-6
INSP
ADJ
E
CONTROL SYSTEM
Shift cable inspection and adjustment
1. Check:
●
Reverse gate stopper lever position
Incorrect
→
Adjust.
Checking steps:
●
Set the shift lever to the reverse posi-
tion.
●
Check that the reverse gate
1
contacts
the stopper
2
on the bracket and the
lever
3
contacts the reverse gate.
●
Set the shift lever to the forward posi-
tion.
●
Check that the lever
4
has been
shifted over the bracket
5
.
4
5
2. Adjust:
●
Shift cable joint
Adjustment steps:
●
Loosen the locknut
1
.
●
Disconnect the cable joint
2
from the
ball joint
3
.
●
Situate the reverse gate to the stopper
on the bracket and the lever to the
reverse gate.
●
Turn the cable joint to align it with the
ball joint.
Turn in
Shortens.
Turn out
Lengthens.
●
Turn out the cable joint nine times
a
to extend cable 7 mm (0.28 in) from
the aligned position.
WARNING
The cable joint must be screwed in more
than 8 mm (0.31 in).
●
Connect the cable joint and tighten the
locknut.
T
R
.
.
Locknut:
3 N • m (0.3 kgf • m, 2.2 ft • lb)