7-38
E
–
+
ELEC
INDICATION SYSTEM
Oil level gauge
1. Check:
●
Oil level gauge
Not operating
→
Replace the multi-
function meter.
Checking steps:
●
Supply DC 12 voltage to the white
four-pin connector (+: red, –: black)
with a battery.
●
Disconnect the white two-pin connec-
tor (blue and black leads).
●
Connect the blue and black terminals
with a jumper lead
1
.
●
Connect the green and red terminals
with a jumper lead
2
.
NOTE:
If the jumper lead is installed for more
than 30 seconds, the display will auto-
matically turn off.
●
Check the oil level segments is full
indicated.
●
Remove the jumper lead from the
white two-pin connector.
●
Disconnect the jumper lead
2
and
then connect it to green and red termi-
nal again.
●
Make sure the oil low level segment
3
, oil level warning indicator
4
,
“
” message
5
and “WARNING”
lamp
6
blink and the buzzer sounds
intermittently.