Registers
763
SPRUH22I – April 2012 – Revised November 2019
Copyright © 2012–2019, Texas Instruments Incorporated
C28 Enhanced Pulse Width Modulator (ePWM) Module
Table 7-62. Trip-Zone Enable Interrupt Register (TZEINT) Field Descriptions (continued)
Bit
Field
Value
Description
0
Reserved
Reserved
Figure 7-113. Trip-Zone Flag Register (TZFLG)
15
8
Reserved
R-0
7
6
5
4
3
2
1
0
Reserved
DCBEVT2
DCBEVT1
DCAEVT2
DCAEVT1
OST
CBC
INT
R-0
R-0
R-0
R-0
R-0
R-0
R-0
R-0
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 7-63. Trip-Zone Flag Register (TZFLG) Field Descriptions
Bit
Field
Value
Description
15:7
Reserved
Reserved
6
DCBEVT2
Latched Status Flag for Digital Compare Output B Event 2
0
Indicates no trip event has occurred on DCBEVT2
1
Indicates a trip event has occurred for the event defined for DCBEVT2
5
DCBEVT1
Latched Status Flag for Digital Compare Output B Event 1
0
Indicates no trip event has occurred on DCBEVT1
1
Indicates a trip event has occurred for the event defined for DCBEVT1
4
DCAEVT2
Latched Status Flag for Digital Compare Output A Event 2
0
Indicates no trip event has occurred on DCAEVT2
1
Indicates a trip event has occurred for the event defined for DCAEVT2
3
DCAEVT1
Latched Status Flag for Digital Compare Output A Event 1
0
Indicates no trip event has occurred on DCAEVT1
1
Indicates a trip event has occurred for the event defined for DCAEVT1
2
OST
Latched Status Flag for A One-Shot Trip Event
0
No one-shot trip event has occurred.
1
Indicates a trip event has occurred on a pin selected as a one-shot trip source.
This bit is cleared by writing the appropriate value to the TZCLR register.
1
CBC
Latched Status Flag for Cycle-By-Cycle Trip Event
0
No cycle-by-cycle trip event has occurred.
1
Indicates a trip event has occurred on a signal selected as a cycle-by-cycle trip source. The
TZFLG[CBC] bit will remain set until it is manually cleared by the user. If the cycle-by-cycle trip
event is still present when the CBC bit is cleared, then CBC will be immediately set again. The
specified condition on the signal is automatically cleared when the ePWM time-base counter
reaches zero (TBCTR = 0x00) if the trip condition is no longer present. The condition on the signal
is only cleared when the TBCTR = 0x00 no matter where in the cycle the CBC flag is cleared.
This bit is cleared by writing the appropriate value to the TZCLR register.
0
INT
Latched Trip Interrupt Status Flag
0
Indicates no interrupt has been generated.
1
Indicates an EPWMx_TZINT PIE interrupt was generated because of a trip condition.
No further EPWMx_TZINT PIE interrupts will be generated until this flag is cleared. If the interrupt
flag is cleared when either CBC or OST is set, then another interrupt pulse will be generated.
Clearing all flag bits will prevent further interrupts.
This bit is cleared by writing the appropriate value to the TZCLR register.