System Control Registers
244
SPRUH22I – April 2012 – Revised November 2019
Copyright © 2012–2019, Texas Instruments Incorporated
System Control and Interrupts
Table 1-131. Peripheral Clock Control Register 1 (PCLKCR1) Register Field Descriptions (continued)
Bit
Field
Value
Description
7-0
EPWMxENCLK
(n = 8-1)
ePWM8-1 Clock Enables
When set, this enables the clock to the respective ePWM module.
0
Clock is disabled
1
Clock is enabled
1.13.7.29 Peripheral Clock Control Register 2 (PCLKCR2)
Figure 1-121. Peripheral Clock Control Register 2 (PCLKCR2)
15
9
8
Reserved
EQEP3ENCLK
R-0:0
R/W-0
7
1
0
Reserved
EPWM9ENCLK
R-0
R/W-0
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 1-132. Peripheral Clock Control Register 2 (PCLKCR2) Register Field Descriptions
Bit
Field
Value
Description
15-9
Reserved
Reserved
8
EQEP3ENCLK
eQEP3 Clock Enable
When set, this enables the clock to the eQEP3 module.
0
eQEP3 clock is disabled
1
eQEP3 clock is enabled
7-1
Reserved
Reserved
0
EPWM9ENCLK
ePWM9 Clock Enable
When set, this enables the clock to the ePWM9 module.
0
ePWM9 clock is disabled
1
ePWM9 clock is enabled