Synergy Series Operation Guide (v18)
Switcher Basics • 4–15
Two Name Mode Conditions and Considerations
With the
2 Names
option selected, the following conditions apply:
•
You can only use the
Small
or
Small Invert Font
options. Choosing other font sizes
either in the Personality Menu or in the naming menus will cause the mnemonic displays
to use the
1 Name
option and display only the non shifted crosspoint names.
•
8 character names are truncated to the 6 characters per row that are displayed. The two
last characters are left off the display.
•
If you select the Standard font option in the naming menus, the mnemonic displays will
still display 2 names in small fonts.
This completes the procedure to configure settings for the Mnemonic Display option.
PIP-II Mem
To use this function, ensure that the
Peripheral Interface II Protocol
option is installed and
configured. If not, please contact
Ross Video
for details.
Refer to the section “
” on page 2–41 for instructions on verifying the
status of installed options. For configuration procedures, refer to the section “
Use the following procedure to enable Synergy memory store and recall functions to all devices:
1. Navigate to the
Personality Menu 3-4
as follows:
•
Press
HOME
B
MORE
B
Setup
B
Personality
B
MORE
B
MORE
.
Personality Menu 3-4
2. Press
PIP-II Mem
to toggle between
Send
and
No Send
as follows:
•
Send
— When
Send
is selected, every time the Synergy does a memory store or
recall, the corresponding command is sent to every PIP-II device to store or recall
its settings in the same memory number as was specified for Synergy. In this way,
the current settings for all of the PIP-II devices can be coordinated with Synergy.
•
No Send
— When
No Send
is selected, no memory commands are sent to
devices. This is the default setting.
This concludes the procedure to enable Synergy memory store and recall functions to all devices.
Refer to the section “
Peripheral Interface II Custom Controls
for information on
configuring custom controls using the PIP-II interface option.
DVE Send
To use the
DVE Send
button for internal Squeeze & Tease wipes, ensure that a Squeeze & Tease card
is installed and configured. If not, please contact
Ross Video
for details.
Содержание SYNERGY 4000DR-003
Страница 1: ...Ross Video Limited Operation Guide Volume I Software Issue 18...
Страница 10: ......
Страница 42: ...1 26 Introduction Synergy Series Operation Guide v18...
Страница 64: ...2 22 Control Panel Introduction Synergy Series Operation Guide v18...
Страница 132: ...4 54 Switcher Basics Synergy Series Operation Guide v18...
Страница 242: ...7 68 Keying Synergy Series Operation Guide v18...
Страница 280: ...8 38 Memory Functions and More Synergy Series Operation Guide v18...
Страница 310: ...GL 4 Glossary of Terms Synergy Series Operation Guide v18...
Страница 332: ...IX 22 Index Synergy Series Operation Guide v18...