Synergy Series Operation Guide (v18)
Control Panel Introduction • 2–9
Electronically, Key 1 is downstream (visually in front) of the MLE’s background buses,
but upstream (visually in back) of Key 2. The
KEY OVER
button allows you to change
that priority.
The layout of the
MLE Key 1 Group
is identical on all three switchers — in all MLEs.
On the Synergy 3 and 4 control panels, the location of the group is identical — to the
right of the
Fader
. On the Synergy 2 panel, the group is located to the left of the
Fader
.
17. MLE Key 2 Group
The
MLE Key 2 Group
allows you to select the key type and associated parameters for
the MLE’s Key 2. Choose between
Self Key
,
Auto Select
(Linear Key),
Chroma Key
,
and
PST Pattern Key
. Within the group, you can also select a variety of parameters and
key transitions. When any button is selected in the group, that MLE’s
Key Bus
is
assigned to Keyer 2. An
ON
LED is provided for tally.
Electronically, Key 2 is downstream (visually in front) of the MLE’s background buses
and downstream of Key 1. The
CHAR GEN
button allows you pick your
favorite CG
for immediate keying.
The layout of the
MLE Key 2 Group
is identical on all three switchers — in all MLEs.
On the Synergy 3 and 4 control panels, the location of the group is identical — to the
right of the
Fader
. On the Synergy 2 panel, the group is located to the left of the
Fader
.
18. Matte Control Group
The
Matte Control Group
is an
assignable
module that allows you to adjust matte,
border, and wash generator colors in the selected MLE. By pressing the desired MLE
button in the group (or by pressing any matte-related button within an MLE itself), the
Matte Control Group
is assigned to that MLE.
Although functionality is identical, the location and layout of the
Matte Control Group
differs all three switchers, due to the differing number of MLE assignment buttons.
19. Effects Control Group
The
Effects Control Group
is an
assignable
module that provides an array of controls
that handle all of the switcher’s frequently used analog-type parameters — such as mask
adjustment, border width, and key clip. By pressing the desired MLE (or downstream)
keyer button in the group (or by pressing any button within an MLE that has associated
adjustable parameters), the
Effects Control Group
is assigned to that MLE.
The location of the
Effects Control Group
is virtually identical on all three switchers
(at the upper right side of the control panel). The layout of the group differs slightly due
to the differing number of MLE keyer assignment buttons.
Operating
Tip
You can also change the priority of the two keyers in the
Key Setup
Menus
by toggling the
Key Over
softkey between
On
and
Off
. Refer
” on page 7-20 for more information.
Содержание SYNERGY 4000DR-003
Страница 1: ...Ross Video Limited Operation Guide Volume I Software Issue 18...
Страница 10: ......
Страница 42: ...1 26 Introduction Synergy Series Operation Guide v18...
Страница 64: ...2 22 Control Panel Introduction Synergy Series Operation Guide v18...
Страница 132: ...4 54 Switcher Basics Synergy Series Operation Guide v18...
Страница 242: ...7 68 Keying Synergy Series Operation Guide v18...
Страница 280: ...8 38 Memory Functions and More Synergy Series Operation Guide v18...
Страница 310: ...GL 4 Glossary of Terms Synergy Series Operation Guide v18...
Страница 332: ...IX 22 Index Synergy Series Operation Guide v18...