Synergy Series Operation Guide (v18)
Custom Controls • 9–9
Programming Relative Custom Controls
Relative Custom Controls store the MLE re-entry position so that they can be taken on-air from any
MLE that is re-entered on the
PGM/PST MLE
. For example, if you have
MLE 2
re-entered into
MLE 3
(
Configuration 1
), of a Synergy 3, and Record a Custom Control on
MLE 2
, you can only
recall that custom control on
MLE 2
, in the same configuration. If, however, you have
MLE 1
re-entered into
MLE 3
(
Configuration 2
), the Relative Custom Control will be recalled on
MLE 1
.
Relative Custom Controls are not MLE specific, as normal custom controls, but instead are re-entry
specific. This means that the re-entry order, or levels that the Relative Custom Control was recorded
on, do not need to be the same in order to recall that custom control. For example, if we again record a
Relative Custom Control on
MLE 2
, of a Synergy 3, which is re-entered into
MLE 3
(
Configuration 1
), we can recall that Relative Custom Control with more or fewer MLEs. If we have
MLE 1
re-entered into
MLE 2
and
MLE 2
re-entered into
MLE 3
(
Configuration 3
), the Relative
Custom Control will be recalled on
MLE 1
. If we have no MLEs re-entered, (
Configuration 4
) the
Relative Custom Control will be recalled on
MLE 3
.
Important
Relative Custom Controls can only be
properly
recorded and recalled
on upper MLEs that are re-entered onto the PGM/PST MLE. If the
MLE is not re-entered, you will not be able to
properly
record or recall
a relative custom control. Instead, the relative custom control will act
like a normal custom control when recalled.
Important
If you record a relative custom control across multiple re-entered
MLEs, at least the same number of MLEs must be re-entered in order
to recall the entire custom control. For example, if a two MLE relative
custom control is recalled on one MLE, the actions to be recalled on
the second MLE will be ignored.
MLE 2
MLE 3
On-Air
Configuration 1
MLE 1
Configuration 2
MLE 3
On-Air
MLE 1
MLE 2
Configuration 3
MLE 3
On-Air
Configuration 4
MLE 3
On-Air
Содержание SYNERGY 4000DR-003
Страница 1: ...Ross Video Limited Operation Guide Volume I Software Issue 18...
Страница 10: ......
Страница 42: ...1 26 Introduction Synergy Series Operation Guide v18...
Страница 64: ...2 22 Control Panel Introduction Synergy Series Operation Guide v18...
Страница 132: ...4 54 Switcher Basics Synergy Series Operation Guide v18...
Страница 242: ...7 68 Keying Synergy Series Operation Guide v18...
Страница 280: ...8 38 Memory Functions and More Synergy Series Operation Guide v18...
Страница 310: ...GL 4 Glossary of Terms Synergy Series Operation Guide v18...
Страница 332: ...IX 22 Index Synergy Series Operation Guide v18...