![Rohde & Schwarz SMBV100B Скачать руководство пользователя страница 912](http://html.mh-extra.com/html/rohde-and-schwarz/smbv100b/smbv100b_user-manual_1477881912.webp)
Remote Control Commands
R&S
®
SMBV100B
910
User Manual 1178.4460.02 ─ 03
Example:
:SYSTem:DATE?
// 2016,05,01
Manual operation:
See
:SYSTem:NTP:HOSTname
<NTPName>
Sets the address of the NTP server. You can enter the IP address, or the hostname of
the time server, or even set up an own vendor zone. See the Internet for more informa-
tion on NTP.
Parameters:
<NTPName>
string
Manual operation:
See
:SYSTem:NTP:STATe
<UseNtpState>
Activates clock synchronization via NTP.
Parameters:
<UseNtpState>
0 | 1 | OFF | ON
*RST:
n.a. (factory preset: 0)
Example:
SYSTem:NTP:STATe 1
Manual operation:
See
:SYSTem:TIME
<Hour>, <Minute>, <Second>
Queries or sets the time for the instrument-internal clock.
This is a password-protected function. Unlock the protection level 1 to access it, see
.
Parameters:
<Hour>
integer
Range:
0 to 23
<Minute>
integer
Range:
0 to 59
<Second>
integer
Range:
0 to 59
Example:
SYSTem:TIME?
// 10,27,14
Manual operation:
See
SYSTem Subsystem