
Configuring the Internal Baseband Source
R&S
®
SMBV100B
221
User Manual 1178.4460.02 ─ 03
3.7.5.1
Triggering in "Next Trigger Mode = Same Segment"
Depending on the trigger setting, the currently selected segment is continuously output
either immediately or after a trigger event.
Table 3-16: Waveform triggering: "Next Trigger Mode = Same Segment", "Trigger Source = Internal"
"Trigger Mode"
Description
"Auto"
Output starts at once and the segment is generated continuously. Trigger events
are ignored.
If the segment is changed in "Segment", output of the current segment is stopped
and the new segment is output immediately, following a system-imposed signal
gap.
"Armed_Auto"
Output starts after the first trigger event. The segment is then generated continu-
ously. Further trigger events are ignored.
If the segment is changed in "Segment", signal output is stopped and the new seg-
ment is not output until a trigger occurs.
"Retrigger"
Output starts at once and the segment is generated continuously, a trigger event
causes a restart.
If the segment is changed in "Segment", output of the current segment is stopped
and the new segment is output immediately, following a system-imposed signal
gap.
"Armed_Retrigger"
Output starts after the first trigger event. The segment is then generated continu-
ously. Further trigger events cause a restart.
If the segment is changed in "Segment", signal output is stopped and the new seg-
ment is not output until a trigger occurs.
"Single"
Output starts after the first trigger event. The segment is then generated once. Fur-
ther trigger events cause a restart.
If the segment is changed in "Segment", signal output is not stopped. The new
segment is not output until a trigger occurs.
3.7.5.2
Triggering in "Next Trigger Mode = Next Segment"
Depending on the trigger setting, the segment selected under "Segment" is output
either immediately or after a trigger event. If the segment index is changed in "Seg-
ment", the new segment is not output until a trigger occurs.
Generating Multi-Segment Waveform Files