![Rohde & Schwarz SMBV100B Скачать руководство пользователя страница 723](http://html.mh-extra.com/html/rohde-and-schwarz/smbv100b/smbv100b_user-manual_1477881723.webp)
Remote Control Commands
R&S
®
SMBV100B
721
User Manual 1178.4460.02 ─ 03
Parameters:
<Angle>
float
Range:
0 to 180
Increment: 0.01
*RST:
0
Default unit: Deg
Example:
BB:DM:FORM AQPS
BB:DM:AQPS:ANGL 45
Manual operation:
See
[:SOURce<hw>]:BB:DM:ASK:DEPTh
<Depth>
Sets the ASK modulation depth for modulation type ASK.
Parameters:
<Depth>
float
Range:
0 to 100
Increment: 0.1
*RST:
100
Default unit: PCT
Example:
BB:DM:FORM ASK
BB:DM:ASK:DEPT 50 PCT
Manual operation:
See
[:SOURce<hw>]:BB:DM:FSK:DEViation
<Deviation>
Sets the frequency deviation when FSK modulation is selected.
Parameters:
<Deviation>
float
The value range depends on the symbol rate.
Range:
1 to 40E6
Increment: 0.5
*RST:
135416.5
Example:
SOURce:BB:DM:FORMat FSK4
SOURce:BB:DM:FSK:DEViation 1MHZ
Manual operation:
See
[:SOURce<hw>]:BB:DM:FSK:VARiable:SYMBol<ch0>:DEViation
<Deviation>
Sets the deviation of the selected symbol for variable FSK modulation mode.
SOURce Subsystem