Configuring the Internal Baseband Source
R&S
®
SMBV100B
236
User Manual 1178.4460.02 ─ 03
..............................................................................................237
Carrier State
Switches the carriers in the range "Carrier Start" to "Carrier Stop" on/off.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:EDIT:CARRier:STATe
Carrier Start/Start
Defines the start/stop index of the carrier range to which the assistant settings are
intended to apply.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:EDIT:CARRier:STARt
[:SOURce<hw>]:BB:ARBitrary:MCARrier:EDIT:CARRier:STOP
Gain Start
Sets the gain of the carrier marked by "Carrier Start".
Remote command:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:EDIT:CARRier:POWer[:STARt]
Gain Step
Sets the step width that is used to increment the gain.
The resulting carrier gain in the carrier table equals:
Gain =
"Gain Start" + n*"Gain Step"
.
Where
n
is a value between 0 and ("Carrier Stop" - "Carrier Start").
Remote command:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:EDIT:CARRier:POWer:STEP
Phase Start
Sets the phase of the carrier marked by "Carrier Start".
Remote command:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:EDIT:CARRier:PHASe[:STARt]
Phase Step
Sets the step width that is used to increment the phase.
The resulting phase in the carrier table equals:
Phase =
"Phase Start" + n*"Phase Step"
Where
n
is a value between 0 and ("Carrier Stop" - "Carrier Start").
Remote command:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:EDIT:CARRier:POWer:STEP
Generating Multi-Carrier Signals