![Rohde & Schwarz SMBV100B Скачать руководство пользователя страница 717](http://html.mh-extra.com/html/rohde-and-schwarz/smbv100b/smbv100b_user-manual_1477881717.webp)
Remote Control Commands
R&S
®
SMBV100B
715
User Manual 1178.4460.02 ─ 03
Manual operation:
See
[:SOURce<hw>]:BB:DM:PRESet
Sets the default settings for digital modulation (
*RST
values specified for the com-
mands).
Not affected is the state set with the command
SOURce<hw>:BB:DM:STATe
Example:
See
Example "Performing general tasks"
Usage:
Event
Manual operation:
See
[:SOURce<hw>]:BB:DM:SRATe
<SRate>
Sets the symbol rated in Hz/kHz/MHz or Symb/s / kSymb/s and MSymb/s.
Parameters:
<SRate>
float
Range:
400 to depends on the installed options
Increment: 0.001
*RST:
270833.333
Default unit: Hz
Example:
See
Example "Performing general tasks"
Manual operation:
See
[:SOURce<hw>]:BB:DM:STANdard
<Standard>
Selects predefined set of settings according to the selected standard, see
Parameters:
<Standard>
USER | BLUetooth | DECT | ETC | GSM | GSMEdge | NADC |
PDC | PHS | TETRa | W3GPp | TDSCdma | CFORward |
CREVerse | WORLdspace | TFTS | APCOPH1C4fm |
APCOPH1CQpsk | APCOPH2HCpm | APCOPH2HDQpsk |
APCOPH2HD8PSKW | APCOPH2HD8PSKN | APCOPH1Lsm |
APCOPH1Wcqpsk
A query returns the value
USER
if one the following is true:
•
A user-defined custom digital modulation setting was loaded
•
One of the associated settings was changed subsequent to the
selection of a standard.
*RST:
GSM
Example:
See
Example "Performing general tasks"
Manual operation:
See