Configuring the Internal Baseband Source
R&S
®
SMBV100B
154
User Manual 1178.4460.02 ─ 03
Create Multi Carrier
Accesses the dialog for creating multi-carrier waveforms (see
Create Test Signal...
Opens the dialog with further setting for the selected
●
Chapter 3.6.3.2, "Sine Test Signals"
●
Chapter 3.6.3.3, "Rectangular Test Signal"
●
Chapter 3.6.3.4, "Constant IQ Test Signal"
Test Signal Form
Selects the form of the test signal. A choice between a sinusoidal, rectangular, or test
signal with constant I/Q is provided.
To access further settings, select
Remote command:
[:SOURce<hw>]:BB:ARBitrary:SIGNal:TYPE
RF Power Ramping with Burst Marker
Option: R&S
SMBVB-K22
If activated, the burst gate marker signal included in the ARB waveform file is used as
marker signal for the pulse modulator.
If this parameter is activated, but the loaded ARB waveform does not contain control
list or the burst gate marker is not defined, the ARB generator cannot be activated. An
error message indicates this situation, too.
You can create the suitable waveform files including the required burst gate marker sig-
nals, for example, with the R&S Pulse Sequencer software.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:PRAMp[:STATe]
Using the Arbitrary Waveform Generator (ARB)