Multi-Instrument Setups
R&S
®
SMBV100B
456
User Manual 1178.4460.02 ─ 03
This function will be supported in a future firmware version.
The "Baseband Input" cannot be activated. However, the baseband input related set-
tings in the "Baseband Input" or "System configuration > External RF and I/Q" are dis-
played and described, as are the respective remote control commands.
These settings have no effect because the baseband input interfaces cannot be activa-
ted.
Required Options
The equipment layout for applying an external baseband signal includes:
●
Base unit
(incl. the digital interfaces Dig I/Q and HS Dig I/Q, where auch of the interfaces can
be used as input or output)
●
Option frequency R&S
SMBVB-B103
For more information, see data sheet.
To access and configure the "Baseband Input" settings
The
"BB Input"
block provides access to the settings for frequency offset and path
gain, and to the available configuration parameters of the external signal.
The digital baseband input interface
Dig I/Q
and
HS Dig I/Q
are located on the
R&S
"Overview of the Baseband Signal Sources"
In the default instrument state, the block diagram displays the connector in an unfolded
state. The digital input interface is inactive.
1. To display the
"BB Input"
block if the connectors are folded, select the connector
symbol "HS Dig I/Q In".
Figure 8-5: Representation of the digital baseband input interface HS Dig I/Q
1 = Digital input interface state: gray =
inactive; blue =
active
2 = Connector name
2. To access the frequency offset settings, select "BB Input > Baseband Offsets".
Chapter 3.10, "Shifting and Boosting the Baseband Signal"
3. To access the dialog box for configuring the external signal input, select "BB Input
> Digital I/Q In > Baseband Input Settings".
The "Baseband Input Settings" dialog provides settings necessary to define the
used connector, and to adjust the signal parameters, like the sample rate and the
baseband input level.
Digital Baseband Input Settings