Remote Control Commands
R&S
®
SMBV100B
728
User Manual 1178.4460.02 ─ 03
Parameters:
<ExtTimeDelay>
float
Range:
0 to 7929.170398682
Increment: 0.25E-9
*RST:
0
Default unit: s
Example:
See
Example "Specifying delay and inhibit values in time units"
Manual operation:
See
"(Specified) External Delay/(Specified) Trigger Delay"
[:SOURce<hw>]:BB:DM:TRIGger[:EXTernal]:RDELay?
Queries the time (in seconds) an external trigger event is delayed for.
Return values:
<ResTimeDelaySec> float
Range:
0 to 688
Increment: 0.25E-9
*RST:
0
Example:
See
Example "Specifying delay and inhibit values in time units"
Usage:
Query only
Manual operation:
See
"Actual Trigger Delay/Actual External Delay"
[:SOURce<hw>]:BB:DM:TRIGger[:EXTernal]:INHibit
<Inhibit>
Specifies the number of symbols by which a restart is inhibited.
Parameters:
<Inhibit>
integer
Range:
0 to 21.47*symbRate
*RST:
0
Default unit: symbol
Example:
See
Example "Adjusting clock, marker and trigger settings"
Manual operation:
See
Marker Settings
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:MODE
<Mode>
Defines the signal for the selected marker output.
For detailed description of the regular marker modes, refer to
SOURce Subsystem