Multi-Instrument Setups
R&S
®
SMBV100B
465
User Manual 1178.4460.02 ─ 03
Access
The analog output connectors I/Q are located on the R&S
SMBV100B rear panel, see
"Overview of the RF Output Signals"
The block diagram displays the "I/Q OUT" connector in a folded state. The analog out-
put connectors are inactive (gray LEDs).
Figure 8-6: Representation of the analog output interface
1 = Analog output interface state: gray =
inactive; blue =
active
2 = Mapped I/Q stream
3 = Analog output connector name
To configure the "I/Q Analog Output" settings
1. Select the "I/Q OUT" symbol to unfold the "I/Q Analog" block.
2. To (re) route the signal to the analog outputs, select the "I/Q Stream Mapper" block.
3. To enable the baseband signal at the analog outputs, select "Block Diagram > I/Q
Analog > I/Q Analog On".
4. To access the dialog box for configuring the analog output signal, select "I/Q Ana-
log > I/Q Analog Settings > General".
The dialog comprises the settings for selecting the analog output signal type (sin-
gle-ended or differential), enabling and generating an RF envelope signal, and add-
ing digital impairments to the signal.
I/Q Analog Output Settings