Remote Control Commands
R&S
®
SMBV100B
723
User Manual 1178.4460.02 ─ 03
Example:
SOURce1:BB:DM:FORMat APSK32
SOURce1:BB:DM:APSK32:GAMMa G9D10
Manual operation:
See
[:SOURce<hw>]:BB:DM:SWITching:STATe
<State>
Enables switching between a modulated and an unmodulated signal.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
0
Example:
SOURce1:BB:DM:SWITching:STATe ON
Manual operation:
See
"State Modulation CW Switching"
Power Ramping
[:SOURce<hw>]:BB:DM:PRAMp:SOURce
<Source>
Sets the source for the power ramp control signals.
Parameters:
<Source>
INTernal
*RST:
INTernal
Example:
See
Example "Enable power ramping"
Manual operation:
See
[:SOURce<hw>]:BB:DM:PRAMp:SHAPe
<Shape>
Sets the edge shape of the ramp envelope.
Parameters:
<Shape>
LINear | COSine
*RST:
COSine
Example:
See
Example "Enable power ramping"
Manual operation:
See
[:SOURce<hw>]:BB:DM:PRAMp:TIME
<Time>
Sets the power ramping rise time and fall time for a burst.
Parameters:
<Time>
float
Range:
0.25 to 16
Increment: 0.01
*RST:
1
Default unit: symbol