Remote Control Commands
R&S
®
SMBV100B
829
User Manual 1178.4460.02 ─ 03
Parameters:
<Increment>
float
Range:
0 Hz to RFmax - 100 kHz
Increment: 0.01 Hz
*RST:
1E6
Example:
See
Example "Frequency configuration"
Manual operation:
See
12.16.7
SOURce:INPut Subsystem
The
SOURce:INPut
subsystem contains the commands for configuring the inputs for
external modulation signals. The instrument trigger setting influences all sweeps and is
effective in the List mode (Instrument Trigger).
[:SOURce<hw>]:INPut:MODext:COUPling
........................................................................829
[:SOURce<hw>]:INPut:MODext:IMPedance<ch>
...............................................................829
................................................................................... 830
[:SOURce<hw>]:INPut:MODext:COUPling
<Coupling>
Selects the coupling mode for an externally applied modulation signal.
Parameters:
<Coupling>
AC | DC
AC
Passes the AC signal component of the modulation signal.
DC
Passes the modulation signal with both components, AC and
DC.
*RST:
AC
Example:
SOURce1:INPut:MODext:COUPling AC
SOURce1:INPut:MODext:IMPedance G50
Manual operation:
See
[:SOURce<hw>]:INPut:MODext:IMPedance<ch>
<Impedance>
Sets the impedance for the externally supplied modulation signal.
Parameters:
<Impedance>
G50 | G600 | HIGH
G50 = 50 Ohm to ground
G600 = 600 Ohm to ground
HIGH = 100 kOhm to ground
*RST:
HIGH
Example:
See
[:SOURce<hw>]:INPut:MODext:COUPling