Configuring the RF Signal
R&S
®
SMBV100B
357
User Manual 1178.4460.02 ─ 03
Remote command:
[:SOURce<hw>]:AM:DEViation:MODE
Total Depth ← AM settings
Sets the sum of the signal
for path 1 and path 2 in per cent when using com-
bined sources and
Using external LF signals, the R&S
SMBV100B indicates the
per Volts for
the input signal.
Provided both signal paths are turned on, the depth of both paths always sum up to the
value of the total depth.
Behavior when changing any depth settings:
●
Changing the total depth adjusts the depths of both paths proportionally.
●
Changing the depth of one path adjusts the depth of the other path. The sum
always results in the set total depth.
Remote command:
Ratio Path2/Path1 ← AM settings
Sets the deviaton ratio of the signal depth for path 2 to path 1 in per cent when using
combined sources.
Using external LF signals, the R&S
SMBV100B indicates the
per Volts for
the input signal.
Remote command:
6.11.4.3
Pulse Generator Settings
Option: see
Chapter 6.11.1, "Required Options"
Access:
► Select "RF" > "Analog Modulation" > "Pulse Generator".
Analog Modulations