![Rohde & Schwarz SMBV100B Скачать руководство пользователя страница 705](http://html.mh-extra.com/html/rohde-and-schwarz/smbv100b/smbv100b_user-manual_1477881705.webp)
Remote Control Commands
R&S
®
SMBV100B
703
User Manual 1178.4460.02 ─ 03
Manual operation:
See
[:SOURce<hw>]:PM:RATio
<Ratio>
Sets the deviation ratio (path2 to path1) in percent.
Parameters:
<Ratio>
float
Range:
0 to 100
Increment: 0.01
*RST:
100
Example:
See
Example "Performing phase modulation"
Manual operation:
See
[:SOURce<hw>]:PM:SENSitivity?
Queries the sensitivity of the externally applied signal for phase modulation.
The returned value reports the sensitivity in
RAD/V. It is assigned to the voltage value
for full modulation of the input.
Return values:
<Sensitivity>
float
Example:
See
Example "Performing phase modulation"
Usage:
Query only
[:SOURce]:PM<ch>[:DEViation]
<Deviation>
Sets the modulation deviation of the phase modulation in RAD.
Parameters:
<Deviation>
float
The maximal deviation depends on the RF frequency and the
selected modulation mode (see data sheet).
Range:
0 to max
Increment: 1
*RST:
1
Default unit: RAD
Example:
See
Example "Performing phase modulation"
Manual operation:
See
12.16.3.5
SOURce:PULM Subsystem
Option: see
Chapter 6.11.1, "Required Options"
SOURce Subsystem