12.3
Lighting and aperture
The lighting setting is in the menu Configure / Device.
As light type (color of the lighting), red light with 660nm wavelength and white light
with 4000°K can be selected. The normal setting for the direction of the lighting is
the 45° quadripartite group. In certain cases, a single-sided lighting can be used.
However, in the ISO/IEC 15415 mode, these cases are not calibrated and thus they
can only be reasonably used in DPM mode.
For testing purposes or for in-depth analyses, the adjustment can be turned off. As
soon as the check mark next to "Use adjustment" is removed, the manual exposure
setting is active.
ATTENTION: Changing the manual exposure setting leads to changed and
non-calibrated measurement results