© REA Elektronik GmbH, Teichwiesenstraße 1 D-64367 Muehltal
REA VeriCube Operating Manual Version 2.16 – 11/2020
Page 113 of 119
Air humidity
max. 80%, relative, non-condensing
Dimensions
200 mm x 150 mm x 150 mm W x L x H)
With keypad width 210 mm
Weight
2,600 g without PoE power supply and cable
Housing protection class
IP 20 when the glass cover or the plastic cover
is slid in.
Maintenance
Monthly calibration and documentation with
the delivered calibration cards and test
equipment monitoring measurements are
necessary. When necessary, clean the lense of
the camera module and the mirror only with
special auxiliary means for optical lenses. If
necessary, clean the glass cover.
Technical data of the available camera modules:
Measuring plane 0mm:
Focal length FoV
Typical X-dimension
Minimum X-dimension
Pixel size
mm
mm
mm
mil
mm
mil
µm
8
114 x 71
0,46
18
0,25
10
44
12
80 x 60
0,31
12
0,18
7
31
16
64 x 47
0,25
10
0,15
6
25
25
37 x 27
0,15
6
0,09
4
14,5
50
9 x 6
0,042
2
0,036
1
3,6
Measuring plane +15mm:
Focal length FoV
Typical X-dimension
Minimum X-dimension
Pixel size
mm
mm
mm
mil
mm
mil
µm
16
68 x 51
0,27
11
0,16
6
27
25
40 x 30
0,16
6
0,10
4
15,7
50
10 x 7
0,05
2
0,04
2
3,9
Measuring plane +45mm:
Focal length FoV
Typical X-dimension
Minimum X-dimension
Pixel size
mm
mm
mm
mil
mm
mil
µm
25
47 x 25
0,2
8
0,10
4
18,4