SV63136 Rev. A
8-17
Scanning • 8
Menu Option
Associated Options/Actions
Count Direction
Allows you to specify the count direction.
•
Up (default),
•
Down, or
•
Random (MC only).
When
Up
is selected, the relevant code’s binary value will
increase as the system scans each page.
When
Down
is selected, the relevant code’s binary value will
decrease as the system scans each page.
Is Controlling
Determines if the selected function controls where collations
end,
or
indicates error checking.
Toggles:
•
Yes (default for EOC)
• No
NOTES:
•
Only one function can be controlling. Selecting "Yes" will
set all other functions to "No".
•
If the Scan Configuration will be used with a closed-loop
file based processing job, then MC
must
be controlling.
This tells the inserter that file based processing will
provide the control instructions to the inserter based on
the MC read on each document and defines this as a
closed-loop Scan Code definition.
Code Base
Allows you to specify the numeric value for the code base.
The minimum value is
2
, and the maximum value is
43
. The
default value is
32
.
For codes that span more than one character, this sets the
value where each character resets to zero and carries to the
next character.
Code Type
Select the appropriate code type:
•
BIN (for most single-bit functions)
•
CCD (for most multi-bit functions)
•
XCD (for minimum code size, this selection allows
multibit fields to span partial characters)
These coding type options are intended to be consecutive
numbers that either count up or count down. They allow the
system to count up to a maximum, or down to either one or
zero and wraps at/to a defined maximum value.
BIN
is a straight binary string. It is loaded into the barcode
construct at the starting bit position until all bits have been
assigned.
CCD
is a character-based field aligned with character
boundaries for human readability. This number must be less
than 43. Recommended options for Code 3 of 9 barcodes
are: 10, 32, or 36. Base number must be 10 for Interleaved 2
of 5 barcodes.
XCD
provides minimum code size at the expense of human
readability. It allows multi-bit fields to span partial characters.
Setting Up
a BCR Scan
Configuration
(continued)
Содержание Relay 5000
Страница 8: ...This page is intentionally blank ...
Страница 10: ...This page is intentionally blank ...
Страница 12: ...SV63136 Rev A This page is intentionally blank ...
Страница 18: ...This page is intentionally blank ...
Страница 20: ...This page is intentionally blank ...
Страница 44: ...This page is intentionally blank ...
Страница 46: ...This page is intentionally blank ...
Страница 92: ...This page is intentionally blank ...
Страница 98: ...This page is intentionally blank ...
Страница 118: ...SV63136 Rev A This page is intentionally blank ...
Страница 120: ...SV63136 Rev A This page is intentionally blank ...
Страница 132: ...This page is intentionally blank ...
Страница 134: ...This page is intensionally blank ...
Страница 148: ...This page is intentionally blank ...
Страница 194: ...This page is intentionally blank ...
Страница 201: ......
Страница 202: ...3001 Summer Street Stamford CT 06926 0700 www pitneybowes com SV63136 Rev A 2015 Pitney Bowes Inc All Rights Reserved ...