84
No.
Name and description
36
TIMING WAIT OUT: Timing wait output
This is the terminal you will use when the link control function with the image checker is configured.
This terminal turns ON when the laser marker enters into the link function operation trigger (TIMING IN)
standby state.
Input TIMING IN (No.24) after making sure that this terminal is turned ON.
37
SCRIPTING OUT: Scripting output
This is the terminal you will use when the link control function with the image checker is configured.
This terminal turns ON while executing scripting (laser marker's internal processing to perform the link control
of the external devices) upon receiving TRIGGER IN (X5). The output time of SCRIPTING OUT does not
include the laser radiation time.
38
N.C.: Not connected
Do not connect externally.
39
N.C.: Not connected
Do not connect externally.
40
N.C.: Not connected
Do not connect externally.
*1 : Set the output time of the one-shot output on the system settings screen of Laser Marker NAVI smart. The setting range is
2 to 510ms. The initial setting value is 40ms. One-shot output time has a small margin of error for the setting value.
ME-LPGS-SM-8
Содержание LP-GS Series
Страница 17: ...1 Product Overview ME LPGS SM 8 ...
Страница 32: ...2 Laser Marker Installation ME LPGS SM 8 ...
Страница 48: ...3 Operation Method ME LPGS SM 8 ...
Страница 68: ...4 External Control Using I O ME LPGS SM 8 ...
Страница 107: ...5 External Control by Communication Commands ME LPGS SM 8 ...
Страница 116: ...6 Link Control with External Devices ME LPGS SM 8 ...
Страница 141: ...7 Maintenance ME LPGS SM 8 ...
Страница 161: ...161 MEMO ME LPGS SM 8 ...
Страница 162: ...Troubleshooting ME LPGS SM 8 ...
Страница 186: ...Index ME LPGS SM 8 ...
Страница 188: ...188 Unit power cable 26 USB 30 45 V Vibration resistance 33 W Warning 177 Z Z axis adjustment module 154 ME LPGS SM 8 ...
Страница 189: ......
Страница 190: ... Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019 ...