93
Item
Time
Remarks
T1
Approx. 10 sec.
Time for system startup. Turn ON the remote mode upon verifying SYSTEM STANDBY
OUT (Y7).
T2
Approx. 8 sec.
Time for completion of laser pumping.
• Normal: Approx. 8 sec.
• Re-pumping right after turning the laser pumping OFF: Approx. 15 sec.
T3
Max. 1 sec.
There is a delay time of around 200ms to max. 1 second from turning ON/OFF of
SHUTTER IN (X8) to turning ON/OFF of SHUTTER OPEN 1 OUT (Y8) and SHUTTER
OPEN 2 OUT (Y9).
SHUTTER OPEN 1 OUT and SHUTTER OPEN 2 OUT will be output by the same
operation, but their output timing has a margin of error.
T4
―
Setup time of the laser marker to start the marking trigger processing.
• In the laser pumping completed state: Total time for shutter opening (T3) and marking
data creation. It varies depending on the quantity of the setting data.
• When the laser pumping is not completed: Total time for shutter opening (T3) and
marking data creation, or time for laser pumping, whichever is longer.
T5
2ms or more
Keep the ON status for 2ms or more.
T6
―
When TRIGGER IN (X5) is accepted, PROCESSING OUT (Y10) turns ON. The output time
of PROCESSING OUT (Y10) includes the trigger delay time, marking preparation time,
laser radiation time, and processing time after marking has completed.
If you are not using the link function with external devices, output time of PROCESSING
OUT (Y10) is almost the same as the total duration of the trigger delay time and LASING
OUT (Y20).
T7
2 to 510ms
One-shot output. Set the output time on the environment setting screen.
There is a small margin of error for the setting value.
ME-LPGS-SM-8
Содержание LP-GS Series
Страница 17: ...1 Product Overview ME LPGS SM 8 ...
Страница 32: ...2 Laser Marker Installation ME LPGS SM 8 ...
Страница 48: ...3 Operation Method ME LPGS SM 8 ...
Страница 68: ...4 External Control Using I O ME LPGS SM 8 ...
Страница 107: ...5 External Control by Communication Commands ME LPGS SM 8 ...
Страница 116: ...6 Link Control with External Devices ME LPGS SM 8 ...
Страница 141: ...7 Maintenance ME LPGS SM 8 ...
Страница 161: ...161 MEMO ME LPGS SM 8 ...
Страница 162: ...Troubleshooting ME LPGS SM 8 ...
Страница 186: ...Index ME LPGS SM 8 ...
Страница 188: ...188 Unit power cable 26 USB 30 45 V Vibration resistance 33 W Warning 177 Z Z axis adjustment module 154 ME LPGS SM 8 ...
Страница 189: ......
Страница 190: ... Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019 ...