4-6-14 Interlock input
If INTERLOCK (X16 - X17 and X18 - X19) is opened, the laser pumping is turned off and the shutter is closed, regardless of
whether or not the laser is radiating. Refer to “Laser marker operation when functions for safety measures are input” (P.77).
T3
T1
T1
T1
T1
T1
T1
T2
T2
T2
T2
T2
T2
T3
T3
T5
T5
T5
T7
T4
T4
T4
T6
TRIGGER IN (X5)
INTERLOCK 1 (X16-X17)
INTERLOCK 2 (X18-X19)
INTERLOCK 1 MONITOR
(Y16-Y17)
ALARM RESET IN (X15)
SHUTTER OPEN 1 OUT (Y8)
SHUTTER OPEN 2 OUT (Y9)
READY OUT (Y5)
PROCESSING OUT (Y10)
PROCESSING END OUT (Y11)
PROCESSING FAIL OUT (Y12)
ALARM OUT (Y15)
INTERLOCK 2 MONITOR
(Y18-Y19)
SHUTTER ENABLE IN (X9)
SHUTTER IN (X8)
LASER SUPPLY IN (X6)
LASER STANDBY OUT (Y6)
ON (Open)
OFF (Close)
ON (Normal)
OFF (Error)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
CLOSE
OPEN
CLOSE
OPEN
CLOSE
OPEN
CLOSE
OPEN
ON
OFF
Marking
interruption
Item
Time
Remarks
T1
Approx. 20ms
INTERLOCK MONITOR is switched open and closed with a delay of approx. 20ms with
reference to each INTERLOCK input.
T2
Max. 1 sec.
There is a delay time of around 200ms to max. 1 second from turning ON/OFF of
SHUTTER IN (X8) to turning ON/OFF of SHUTTER OPEN 1 OUT (Y8) and SHUTTER
OPEN 2 OUT (Y9). SHUTTER OPEN 1 OUT and SHUTTER OPEN 2 OUT will be output
by the same operation, but their output timing has a margin of error.
T3
100ms or more
Keep the ON status for 100ms or more.
T4
Approx. 8 to 15 sec.
Time for completion of laser pumping.
• Normal: Approx. 8 sec.
• Re-pumping right after turning the laser pumping off: Approx. 15 sec.
T5
―
Total time for shutter opening and marking data creation, or time for laser pumping,
whichever is longer.
T6
2ms or more
Keep the ON status for 2ms or more.
T7
2 to 510ms
This is One-shot output. Set the output time on the environment setting screen. There is
a small margin of error for the setting value.
ME-LPGS-SM-8
Содержание LP-GS Series
Страница 17: ...1 Product Overview ME LPGS SM 8 ...
Страница 32: ...2 Laser Marker Installation ME LPGS SM 8 ...
Страница 48: ...3 Operation Method ME LPGS SM 8 ...
Страница 68: ...4 External Control Using I O ME LPGS SM 8 ...
Страница 107: ...5 External Control by Communication Commands ME LPGS SM 8 ...
Страница 116: ...6 Link Control with External Devices ME LPGS SM 8 ...
Страница 141: ...7 Maintenance ME LPGS SM 8 ...
Страница 161: ...161 MEMO ME LPGS SM 8 ...
Страница 162: ...Troubleshooting ME LPGS SM 8 ...
Страница 186: ...Index ME LPGS SM 8 ...
Страница 188: ...188 Unit power cable 26 USB 30 45 V Vibration resistance 33 W Warning 177 Z Z axis adjustment module 154 ME LPGS SM 8 ...
Страница 189: ......
Страница 190: ... Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019 ...